Journal of Nuclear Fuel Cycle and Waste Technology 2015;13(2):99-112. Published online: Jun, 30, 2015
DOI : dx.doi.org/10.7733/jnfcwt.2015.13.2.99
In this study, laboratory test equipment was designed and installed to evaluate the thermal behavior of bentonite, which is used as a buffer in high-level waste disposal systems. The thermal analysis was conducted to verify the test results using ABAQUS, a finite element analysis code. In view of the seasonal changes seen during the test, the thermal behavior of bentonite with a temperature of outside air was evaluated. Of the cases examined, the results of the analysis model using stainless steel (Case 3) approximates to the test results, showing an error of about 1℃. The results of the thermal analysis into seasonal temperature distributions are consistent with trends seen in lab-test results. These analyses show that the effects of the thermal conductivity of the material surrounding the buffer and outside air temperature, are very important factors in the thermal behavior of bentonite. In the future, it is expected that a moisture saturation test of a bentonite buffer containing a heat source will be carried out. Therefore, the development of a numerical analysis model is required for the prediction and verification of the laboratory test results.
Keywords
Laboratory test,Bentonite,ABAQUS,Thermal conductivity,Thermal behavior