Review

  • Journal of Nuclear Fuel Cycle and Waste Technology
  • Volume 16(2); 2018
  • Article

Journal of Nuclear Fuel Cycle and Waste Technology 2018;16(2):223-232. Published online: Jun, 30, 2018

Porous Media Modelling and Verification of Thermal Analysis for Inlet and Outlet Ducts of Spent Fuel Storage Cask

  • Ju-Chan Lee, Kyung-Sik Bang, Woo-Seok Choi, Ki-Seog Seo, Sungho Ko
Abstract

Bird screen meshes are installed at the air inlet and outlet ducts of spent fuel storage casks to inhibit the intrusion of debris from the external environment. The presence of these screens introduces an additional resistance to air flow through the ducts. In this study, a porous media model was developed to simplify the bird screen meshes. CFD analyses were used to derive and verify the flow resistance factors for the porous media model. Thermal analyses were carried out for concrete storage cask using the porous media model. Thermal tests were performed for concrete casks with bird screen meshes. The measured temperatures were compared with the analysis results for the porous model. The analysis results agreed well with the test results. The analysis temperatures were slightly higher than the test temperatures. Therefore, the reliability and conservatism of the analysis results for the porous model have been verified.

Keywords

Spent fuel,Concrete storage cask,Thermal analysis,Thermal test,Bird screen,Natural convection,Heat removal,Porous media