Journal of Nuclear Fuel Cycle and Waste Technology 2006;4(4):353-363. Published online: Dec, 30, 2006
In order to evaluate the potential radiological risks for the reuse of the site after decommissioning of nuclear facilities, a mathematical model was developed and materialized into the Microsoft Excel® spreadsheets frame. A set of input parameter values was proposed, which is useful in the preliminary risk screening step before the detailed evaluation with the site-specific data. It appeared that the screening levels calculated by the present model was agreed with the derived concentration guideline limits resulted from RESRAD Ver.6.2 and the German dose criteria for releasing a nuclear site from regulatory control.
Keywords
Decommissioning,Site Reuse,Screening,Radiological risk